of 8
Current View
RP002-400Safety Data Sheetaccording to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/830Date of issue: 2015/10/27Revision date: 2018/02/26Version: 2.32018/03/07EN (English)1/ 8SECTION 1: Identification of the substance/mixture and of the company/undertaking1.1.Product identifierProduct form: MixtureTrade name:Product code:Vaporizer:AerosolProduct group: Trade product1.2.Relevant identified uses of the substance or mixture and uses advised against1.2.1.Relevant identified usesIndustrial/Professional use spec: IndustrialFor professional use only1.2.2.Uses advised againstNo additional information available1.3.Details of the supplier of the safety data sheet1.4.Emergency telephone numberEmergency number: 900 15 20 40SECTION 2: Hazards identification2.1.Classification of the substance or mixtureClassification according to Regulation (EC) No. 1272/2008 [CLP]Mixtures: SDS < 2015 : Show CLP information + DPD classification in section 2.1Aerosol, Category 1H222;H229Full text of H statements : see section 16Classification according to Directive 67/548/EEC [DSD] or 1999/45/EC [DPD]F+; R12Full text of R-phrases: see section 16Adverse physicochemical, human health and environmental effectsNo additional information available2.2.Label elementsLabelling according to Regulation (EC) No. 1272/2008 [CLP]Extra labelling to displayExtra classification(s) to displayHazard pictograms (CLP):GHS02Signal word (CLP): DangerHazard statements (CLP): H222 - Extremely flammable aerosol.H229 - Pressurised container: May burst if heated.Precautionary statements (CLP): P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.P211 - Do not spray on an open flame or other ignition source.P251 - Do not pierce or burn, even after use.P410+P412 - Protect from sunlight. Do not expose to temperatures exceeding 50 °C, 122 °F.EWS GmbHSiemensstr. 89 - D47574 Goch - GermanyTel.: +49 (0)2823 87996-0 - Fax: +49 (0)2823 87996-29email: info@ewsgmbh.com - www.ewsgmbh.comRP002-400CERAMICRP002-400Safety Data Sheetaccording to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/830Date of issue: 2015/10/27 Revision date: 2018/02/26 Version: 2.3
RP002-400Safety Data Sheetaccording to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/8302018/03/07EN (English)2/ 82.3.Other hazardsNo additional information availableSECTION 3: Composition/information on ingredients3.1.SubstancesNot applicable3.2.MixturesNameProduct identifier%Classification according to Directive 67/548/EECClassification according to Regulation (EC) No.1272/2008 [CLP]Hydrocarbons, C3-4-rich, petroleumdistillate, Petroleum gas(CAS-No.)68512-91-4(EC-No.)270-990-9(EC Index-No.)649-083-00-040-50F+; R12Flam. Gas 1, H220Press. GasFull text of R- and H-statements: see section 16SECTION 4: First aid measures4.1.Description of first aid measuresFirst-aid measures general:Never give anything by mouth to an unconscious person. If you feel unwell, seek medical advice (show the label where possible).First-aid measures after inhalation: Assure fresh air breathing. Allow the victim to rest.First-aid measures after skin contact: Remove affected clothing and wash all exposed skin area with mild soap and water, followedby warm water rinse.First-aid measures after eye contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present andeasy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.First-aid measures after ingestion: Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.4.2.Most important symptoms and effects, both acute and delayedSymptoms/effects: Not expected to present a significant hazard under anticipated conditions of normal use.4.3.Indication of anyimmediate medical attention and special treatment neededNo additional information availableSECTION 5: Firefighting measures5.1.Extinguishing mediaSuitable extinguishing media: Foam. Dry powder. Carbon dioxide. Water spray. Sand.Unsuitable extinguishing media: Do not use a heavy water stream.5.2.Special hazards arising from the substance or mixtureNo additional information available5.3.Advice for firefightersFirefighting instructions: Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.Protection during firefighting:Do not enter fire area without proper protective equipment, including respiratory protection.SECTION 6: Accidental release measures6.1.Personal precautions, protective equipment and emergency procedures6.1.1.For non-emergency personnelEmergency procedures: Evacuate unnecessary personnel.6.1.2.For emergency respondersProtective equipment:Equip cleanup crew with proper protection.Emergency procedures:Ventilate area.6.2.Environmental precautionsPrevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters.6.3.Methods and material for containment and cleaning upMethods for cleaning up: Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collectspillage. Store away from other materials. Collect all waste in suitable and labelled containersand dispose according to local legislation.6.4.Reference to other sectionsSee Heading 8. Exposure controls and personal protection.